1.Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.
2.Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information.
3.The table above shows specifications for using petroleum based oils.Pumps (customized design) for special fluids are also available. Their operating pressure and maximum shaft speed however differ from the values in the table above depending on the fluid type.Range of operating temperature and viscosities may differ from those of petroleum based oils due to their characteristics.
Model Numbers | A37-F-R-01-H-K-32 | |
Geometric Displacement cm /rev (cu. in. /rev) | 36.9 (2.25) | |
Minimum Adj. Flow 3 cm /rev (cu. in. /rev) | 10 (.610) | |
Operating Presure MPa (PSI) | Rated | 16 (2320) |
Intermittent | 21 (3050) | |
Shaft Speed Ranger/min | Max. | 1800 |
Min. | 600 | |
Approx. Mass kg (lbs.) | Flange Mtg. | 28.0 (61.7) |
Foot Mtg. | 32.3 (71.2) |
Over the years, we have been committed to the production and research of “A” Series Variable Displacement Piston Pumps.We not only provide high quality machinery and accessories for sale on the market, we also care about customers’ profits and the impact of machinery on the environment.If you want to know more details, please contact us immediately!
A37-F-R-01-H-K-32 | A Series Variable Piston Pump, Single Please check the type/dimensions/specifications of the part A37-F-R-01-H-K-32 in the A Series Variable Piston Pump, Single Stage Pump, Pressure.
Houston Hydraulic > Yuken > Piston Pumps > Axial Pistion A37-F-L-04-H-K-32. Piston Pump, Proportional Load Sense Comp., 290 – 2990 … A37-F-R-01-H-K-32. Piston Pump, Pressure Comp 170 – 2050 psi. Rotation.
A Series Variable Displacement Piston Pumps Dec 3, 2016 – A. Series Variable Displacement Piston Pumps. A10. A16. A22. A37 ….. 32. A56. (56.2 cm3/rev). 32. A70. -F. R. 01. B. S. -60. Series Number.