Yuken A16-F-R-01-C-K-32 Pump

1.Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.

2.Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information.

3.The table above shows specifications for using petroleum based oils.Pumps (customized design) for special fluids are also available. Their operating pressure and maximum shaft speed however differ from the values in the table above depending on the fluid type.Range of operating temperature and viscosities may differ from those of petroleum based oils due to their characteristics.

Model NumbersA16-F-R-01-C-K-32 
Geometric Displacement cm /rev (cu. in. /rev)15.8 (.964) 
Minimum Adj. Flow 3 cm /rev (cu. in. /rev)4 (.244) 
Operating Presure MPa (PSI)Rated16 (2320)
Intermittent21 (3050)
Shaft Speed Ranger/minMax.1800
Min.600
Approx. Mass kg (lbs.)Flange Mtg.16.5 (36.4)
Foot Mtg.18.7 (41.2)

Over the years, we have been committed to the production and research of “A” Series Variable Displacement Piston Pumps.We not only provide high quality machinery and accessories for sale on the market, we also care about customers’ profits and the impact of machinery on the environment.If you want to know more details, please contact us immediately!

Yuken A16-FR-01-HK-32 Variable Displacement Piston Pump A145-FR04HBS-1DD-22-R, A37-L-R-05-C-S-K-32. A145-FR04HBS-A-60366, A40-F-R-01-C-K-32. A16-F-R-01-H-K-32, A45-F-R-01-B-K-32. A16-L-R-01-B-K-32.

A Series Variable Displacement Piston Pumps The maximum operating pressure for each double pump depends on its ….. 32. A56. (56.2 cm3/rev). 32. A70. -F. R. 01. B. S. -60. Series Number.