Yuken PV2R1-6-F-RAA-4222 Pump

These pumps are of high pressure and high performance, which have been developed especially for low noise operation. To comply with a variety of applications including injection moulding machines, PV2R series single pumps provide the output flow of such a wide range as from 5.8 to 237 cm3/rev (.354 to 14.46 cu.in./rev). The intergral driving parts of the pumps are combined into a kit form and available for supply as a cartridge kit. Therefore, the replacement of the driving parts can be done easily. Specifications: Model Numbers PV2R1-6-F-RAA-4222 Geometric Displacement cm3/rev (cu.in./rev) 5.8 (  .354 ) Max. Operating Pressure     MPa … Read more

Yuken A145-F-R-01-C-S-60 Pump

1.Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure. 2.Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information. 3.The table above shows specifications for using petroleum … Read more

Yuken A90-F-R-01-C-S-60 Pump

1.Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure. 2.Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information. 3.The table above shows specifications for using petroleum … Read more

Yuken A70-F-R-01-C-S-60 Pump

1.Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure. 2.Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information. 3.The table above shows specifications for using petroleum … Read more

Yuken A56-F-R-01-C-K-32 Pump

1.Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure. 2.Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information. 3.The table above shows specifications for using petroleum … Read more

Yuken A37-F-R-01-H-K-32 Pump

1.Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure. 2.Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information. 3.The table above shows specifications for using petroleum … Read more

Yuken A22-F-R-01-C-K-32 Pump

1.Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure. 2.Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information. 3.The table above shows specifications for using petroleum … Read more

Yuken A16-F-R-01-C-K-32 Pump

1.Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure. 2.Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information. 3.The table above shows specifications for using petroleum … Read more

Yuken A10-F-R-01-C-K-10 Pump

1.Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure. 2.Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information. 3.The table above shows specifications for using petroleum … Read more

Yuken ARL1-16-FR01A-10 Pump

Features: Low noise and high reliability based on the long established experience The noise at full cut-off with a pressure of 7 MPa, pump rotational speed of 1500 r/min, and measured distance of 1 m is as low as 55 dB(A) (representative value of ARL1-16).  This series also has a high reliability based on Yuken’s long-time experience of manufacturing piston pumps. Lightweight and compact Compared to the AR Series Variable Displacement Piston Pumps, this series is reduced by 40 % both in mass and volume, realizing a greatly lightweight and compact design. Specifications: Model Numbers ARL1-16-FR01A-10 Geometric Displacement cm3/rev  16.3 … Read more